Function library
19.1
Function blocks
1590
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Outputs
Parameter
Identifier
Data type
Value/meaning
dnPosOut_1_p
...
dnPosOut_8_p
DINT
Detected positions
dnDeltaPos_12_p
dnDeltaPos_23_p
dnDeltaPos_34_p
...
dnDeltaPos_18_p
DINT
Calculated distances between the detected positions
• dnDeltaPos_12_p = Distance between dnPosOut_1_p and dnPosOut_1_p
• dnDeltaPos_23_p = Distance between dnPosOut_2_p and dnPosOut_3_p
• dnDeltaPos_34_p = Distance between dnPosOut_3_p and dnPosOut_4_p
...
• dnDeltaPos_18_p = Distance between dnPosOut_1_p and dnPosOut_8_p
wLastMeasure
WORD
Memory location number (1 ... 8) of the last measurement
Parameter
Possible settings
Info
Memory length
• Lenze setting: 7 measurements
1 1 measurement
2 2 measurements
... ...
7 7 measurements
Memory type
• Lenze setting: No ring buffer
0 No ring buffer
1 Ring buffer
Input selection
• Lenze setting: Pos input
0 Pos input
1 V input
Edge selection
• Lenze setting: HIGH edge
0 High edge
1 Low edge
2 High and low edge