5 setting parameters (short overview), Setting parameters (short overview), 8technology applications – Lenze 8400 TopLine User Manual
Page 452
![background image](/manuals/566308/452/background.png)
8
Technology applications
8.2
TA "Actuating drive speed"
452
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
8.2.5
Setting parameters (short overview)
Parameter
Info
Lenze setting
Value Unit
Accel. time - main setpoint
2.000 s
Decel. time - main setpoint
2.000 s
Auto-DCB: Threshold
3 rpm
LS_DriveInterface: bNActCompare
0.00 %
DCB braking: Current
50.00 %
Fixed setpoint 1
40.00 %
Fixed setpoint 2
60.00 %
Fixed setpoint 3
80.00 %
Fixed setpoint 4 ... 15
0.00 %
Add. accel. time 1 ... 15
0.000 s
Add. decel. time 1 ... 15
0.000 s
Decel. time - quick stop
2.000 s
Auto-DCB: Hold time
0.500 s
DCB braking: Hold time
999.000 s
L_NSet_1: Ramp smoothing
0: Off
L_NSet_1: S-ramp time PT1
20.00 s
L_NSet_1: Setpoint arithmetic
0: Out = Set
L_NSet_1: Acceleration time - add. setpoint
0.000 s
L_NSet_1: Deceleration time - add. setpoint
0.000 s
L_PCTRL_1: Vp
1.0
L_PCTRL_1: Tn
400 ms
L_PCTRL_1: Kd
0.0
L_PCTRL_1: MaxLimit
199.99 %
L_PCTRL_1: MinLimit
-199.99 %
L_PCTRL_1: Acceleration time
0.010 s
L_PCTRL_1: Deceleration time
0.010 s
L_PCTRL_1: Root function
0: Off
L_NSet_1: Hyst. NSet reached
0.50 %
Operating mode of process controller
0: Off
L_PCTRL_1: Accel. time influence
5.000 s
L_PCTRL_1: Deceleration time influence
5.000 s
L_NSet_1: Blocking speed 1 max
0.00 %
L_NSet_1: Blocking speed 2 max
0.00 %
L_NSet_1: Blocking speed 3 max
0.00 %
L_NSet_1: Blocking speed 1 min
0.00 %
L_NSet_1: Blocking speed 2 min
0.00 %
L_NSet_1: Blocking speed 3 min
0.00 %
L_NSet_1: nMaxLimit
199.99 %
L_NSet_1: nMinLimit
-199.99 %
L_OffsetGainP_1: Gain
1.0000
L_OffsetGainP_2: Gain
1.0000
L_OffsetGainP_3: Gain
1.0000