C00039 | fixed setpoint x (l_nset_1 n-fix), C00050 | mctrl: speed setpoint, C00051 | mctrl: actual speed value – Lenze 8400 TopLine User Manual
Page 896: C00051, C00039/1, C00039/2, C00039/3, Is used, E (display in, As well as th
17
Parameter reference
17.2
Parameter list | C00039
896
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00039
C00050
C00051
Parameter | Name:
C00039 | Fixed setpoint x (L_NSet_1 n-Fix)
Data type: INTEGER_16
Index: 24536
d
= 5FD8
h
FB: Fixed speed setpoints (JOG values) for the setpoint generator
Setting range
(min. value | unit | max. value)
-199.99
%
199.99
Subcodes
Lenze setting
Info
C00039/1
40.00 %
Fixed setpoint 1
C00039/2
60.00 %
Fixed setpoint 2
C00039/3
80.00 %
Fixed setpoint 3
C00039/4
0.00 %
Fixed setpoint 4
C00039/5
0.00 %
Fixed setpoint 5
C00039/6
0.00 %
Fixed setpoint 6
C00039/7
0.00 %
Fixed setpoint 7
C00039/8
0.00 %
Fixed setpoint 8
C00039/9
0.00 %
Fixed setpoint 9
C00039/10
0.00 %
Fixed setpoint 10
C00039/11
0.00 %
Fixed setpoint 11
C00039/12
0.00 %
Fixed setpoint 12
C00039/13
0.00 %
Fixed setpoint 13
C00039/14
0.00 %
Fixed setpoint 14
C00039/15
0.00 %
Fixed setpoint 15
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00050 | MCTRL: Speed setpoint
Data type: INTEGER_32
Index: 24525
d
= 5FCD
h
Display of the speed setpoint at the speed setpoint input of the motor control
Display range
(min. value | unit | max. value)
-120000
rpm
120000
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00051 | MCTRL: Actual speed value
Data type: INTEGER_32
Index: 24524
d
= 5FCC
h
Display of the actual speed value of the motor shaft
Note:
The displayed value only corresponds to the real actual speed value of the motor shaft if an encoder is connected to
the motor and the evaluation of the feedback signal has been set correctly ("Closed loop" operation).
In case of operation without speed feedback, the signal is calculated from the motor control and thus may not
correspond to the real actual speed.
Display range
(min. value | unit | max. value)
-120000
rpm
120000
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1