C00233 | l_pctrl_1: root function, C00234 | oscillation damping influence, C00235 | oscillation damping filter time – Lenze 8400 TopLine User Manual
Page 941: C00236 | field weakening oscillation damping, C00241 | l_nset_1: hyst. nset reached, C00234, C00236, Is increased, th, N damping, C00235
![background image](/manuals/566308/941/background.png)
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
941
17
Parameter reference
17.2
Parameter list | C00233
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00233
C00234
C00235
C00236
C00241
Parameter | Name:
C00233 | L_PCTRL_1: Root function
Data type: UNSIGNED_8
Index: 24342
d
= 5F16
h
FB: Use of the root function at the actual value input
Selection list
(Lenze setting printed in bold)
Info
0 Off
Root function inactive
• The actual value nAct_a remains unchanged for
further processing
1 On
Root function active
• The root is extracted of the actual value nAct_a for
further processing
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00234 | Oscillation damping influence
Data type: UNSIGNED_16
Index: 24341
d
= 5F15
h
Setting range
(min. value | unit | max. value)
Lenze setting
0.00
%
250.00 5.00 %
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00235 | Oscillation damping filter time
Data type: UNSIGNED_8
Index: 24340
d
= 5F14
h
Setting range
(min. value | unit | max. value)
Lenze setting
2
ms
250 32 ms
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00236 | Field weakening oscillation damping
Data type: UNSIGNED_8
Index: 24339
d
= 5F13
h
Oscillation damping for idling machines
Setting range
(min. value | unit | max. value)
Lenze setting
0
40 14
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00241 | L_NSet_1: Hyst. NSet reached
Data type: INTEGER_16
Index: 24334
d
= 5F0E
h
FB: Hysteresis window for the zero detection of the speed output setpoint
• The speed threshold for the zero detection is 1 %
Setting range
(min. value | unit | max. value)
Lenze setting
0.00
%
100.00 0.50 %
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100