5 activate/deactivate quick stop, Activate/deactivate quick stop, Activate/deactivate quick stop ( 108) – Lenze 8400 TopLine User Manual
Page 108: 4device control (dctrl)
4
Device control (DCTRL)
4.1
Device commands (C00002/x)
108
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
4.1.5
Activate/deactivate quick stop
The
= "1: On / start" device command activates the quick stop function, i.e. the motor
control is separated from the setpoint selection, and within the deceleration time parameterised
the motor is brought to a standstill (n
act
= 0).
• The motor is kept at a standstill during closed-loop operation.
• A pulse inhibit is set if the auto-DCB function has been activated via
.
•
From version 02.00.00
, further options for the quick stop function can be activated in
.
•
provides a bit coded representation of all active sources/triggers of a quick stop:
Deactivate quick stop again
The
= "0: Off / ready" device command deactivates the quick stop again, provided that
no other source of a quick stop is active.
Parameter
Info
Lenze setting
Value Unit
Decel. time - quick stop
2.000 s
Bit Cause/source for quick stop
Bit 0
Reserved
Bit 1 CAN control word (bit 2)
Bit 2 MCI control word (bit 2)
Bit 3
Reserved
Bit 4 Application (
system block: bQspOn input)
Bit 5 Device command (
)
Bit 6 Device error with "TroubleQSP" error response
Bit 7 Internal signal
Bit 8
Reserved
Bit 9
Reserved
Bit 10 Operating system
Bit 11
Reserved
Bit 12 MCK (System block
: Input bQspOn)
Bit 13
Reserved
Bit 14
Reserved
Bit 15
Reserved