6 enable controller and test application, Enable controller and test application, 3commissioning – Lenze 8400 TopLine User Manual
Page 80: Stop
3
Commissioning
3.8
Commissioning of the "Table positioning" technology application
80
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
More detailed information on the technology application:
Internal interfaces | application block "LA_TabPos"
Process data assignment for fieldbus communication
Terminal assignment of the control modes
Setting parameters (short overview)
3.8.5
Saving parameter settings safe against mains failure
The parameter set must be saved to the device safe against mains failure to prevent parameter
settings becoming lost due to mains switching.
Save parameter set.
3.8.6
Enable controller and test application
If the controller is in the "
" status:
1. Enable controller: Set terminal X5/RFR to HIGH level or close contact.
• If there is no other active source for the controller inhibit, the controller changes from the
"
• The Diagnostics tab and
display all active sources for the controller inhibit.
2. Select the respective control signals via the digital inputs (see sections below).
Stop!
Before stipulating a speed setpoint, check whether the brake in the form of a holding
brake on the motor shaft has been released!
Note!
If the controller is enabled and the "Inhibit at power-on" auto-start option is activated in
(Lenze setting) when the mains is connected, the controller remains in the
"
" state.
To be able to change to the "
" status, the controller enable must be
deactivated first: set terminal X5/RFR to LOW level.
Note!
Observe the actual speed value (display in
.