Parameter reference
17.2
Parameter list | C01220
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01220
Parameter | Name:
C01220 | MCK: Ref. setting
Data type: UNSIGNED_16
Index: 23355
d
= 5B3B
h
From version 14.00.00
Settings for "homing" mode
Setting range
(min. hex value | max. hex value)
0x0000
0xFFFF
Value is bit-coded:
Info
Bit 0
Reserved
Bit 1
Reserved
Bit 2
Reserved
Bit 3
Reserved
Bit 4 Start deletes bHomePosAvailable
1 ≡ When homing is started (mode 4 ... 15), the reference
information is deleted.
Bit 5 Maximum jerk
1 ≡ The maximum jerk is calculated based on the
acceleration and S-ramp time of the current profile and
the sequence profile. This is then used in an accelerated
drive for reducing the acceleration to 0 or for
acceleration of the sequence profile.
Setting or activation of maximum jerk for traversing
Bit 6
Reserved
Bit 7
Reserved
Bit 8
Reserved
Bit 9
Reserved
Bit 10
Reserved
Bit 11
Reserved
Bit 12
Reserved
Bit 13
Reserved
Bit 14
Reserved
Bit 15
Reserved
Subcodes
Lenze setting
Info
C01220/1
0x0000
MCK: Ref. setting
Read access Write access CINH PLC STOP No transfer COM MOT