Motor temperature monitoring (KTY) via resolver
The sensor type has to be selected in
.
• If the winding temperature detected via the motor temperature sensor reaches the limit value
(Lenze setting: 120 °):
• An advance warning in the form of the error response set in
is issued.
• The "
oH7: Motor temperature - resolver > C121
" error message is entered into the logbook.
• If the fixed limit value of 150 °C is reached:
• The error response set in
• The "
oH9: Motor temperature - resolver
" error message is entered into the logbook.
• If open circuit is detected for the motor temperature sensor:
• The error response set in
• The "
Sd6: Thermal detector error - resolver
" error message is entered into the logbook.
Parameter
Info
Lenze setting
Value Unit
Motor temp. feedback system
0: Speed feedback
Motor temperature
- °C
Resolver
Motor temperature via resolver
- °C
Warning threshold motor temperature resolver
120 °C
Resp. to motor overtemp. KTY resolver
1: Fault
Resp. to motor temp. > C00121 resolver
5: Warning
Resp. to temp. sensor error KTY resolver
1: Fault
Type of motor temperature sensor resolver
0: KTY83-110 °C
Multi encoder
Motor temperature via MultiEncoder
- °C
Warning threshold motor temperature MultiEncoder
120 °C
Resp. to motor overtemp. KTY MultiEncoder
1: Fault
Resp. to motor temp. > C00121 encoder
5: Warning
Resp. to temp. sensor error KTY MultiEncoder
1: Fault
Type of motor temperature sensor MultiEncoder
0: KTY83-110 °C