7i/o terminals – Lenze 8400 TopLine User Manual
Page 418
7
I/O terminals
7.4
Touch probe detection
418
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Outputs
bEnableTPResolverWindow
BOOL
(from version 12.00.00)
Z-track of resolver: Activate acceptance window
TRUE Acceptance window function is active:
• If the actual position is outside the acceptance window, whose
and whose end position is set
in
, touch probe is automatically deactivated.
Output
Data type
Value/meaning
bTPDigIn3...7Received
BOOL
TRUE DI3 ... DI7: Touch probe received.
• The signal is only pending for one task cycle (1 ms).
bTPEncoderReceived
BOOL
(from version 12.00.00)
TRUE Z-track of encoder: Touch probe received.
• The signal is only pending for one task cycle (1 ms).
bTPResolverReceived
BOOL
(from version 12.00.00)
TRUE Z-track of resolver: Touch probe received.
• The signal is only pending for one task cycle (1 ms).
dnTPDigIn3...7_Position_p
DINT
DI3 ... DI7: Position measured by touch probe in [increments]
dnTPEncoder_Position_p
DINT
(from version 12.00.00)
Z track of encoder: Position measured by touch probe in [increments]
dnTPResolver_Position_p
DINT
(from version 12.00.00)
Z track of resolver: Position measured by touch probe in [increments]
Input
Data type
Information/possible settings