C01020 | l_odometer_1: memory length, C01021 | l_odometer_1: memory type, C01022 | l_odometer_1: input selection – Lenze 8400 TopLine User Manual
Page 1140: C01023 | l_odometer_1: edge selection, 17 parameter reference
![background image](/manuals/566308/1140/background.png)
17
Parameter reference
17.2
Parameter list | C01020
1140
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01020
C01021
C01022
C01023
Parameter | Name:
C01020 | L_Odometer_1: Memory length
Data type: UNSIGNED_8
Index: 23555
d
= 5C03
h
FB
: No. of measurements
Selection list
(Lenze setting printed in bold)
1 1 measurement
2 2 measurements
3 3 measurements
4 4 measurements
5 5 measurements
6 6 measurements
7 7 measurements
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01021 | L_Odometer_1: Memory type
Data type: UNSIGNED_8
Index: 23554
d
= 5C02
h
FB
: If "ring buffer" is selected, it is started again after the measurements set in
and the old
values are overwritten. Otherwise, the measurement stops.
Selection list
(Lenze setting printed in bold)
0 No ring buffer
1 Ring buffer
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01022 | L_Odometer_1: Input selection
Data type: UNSIGNED_8
Index: 23553
d
= 5C01
h
FB
: Selection of position or speed input
Selection list
(Lenze setting printed in bold)
0 Pos input
1 V input
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01023 | L_Odometer_1: Edge selection
Data type: UNSIGNED_8
Index: 23552
d
= 5C00
h
FB
: No. of the edge triggering the measurement
Selection list
(Lenze setting printed in bold)
0 High edge
1 Low edge
2 High and low edge
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1