C00428 | ssi encoder: coding, C00430 | ls_multiencoder: max. initialization time, C00430/1 – Lenze 8400 TopLine User Manual
Page 974: C00428, 17 parameter reference
![background image](/manuals/566308/974/background.png)
17
Parameter reference
17.2
Parameter list | C00428
974
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00428
C00430
Parameter | Name:
C00428 | SSI encoder: Coding
Data type: UNSIGNED_8
Index: 24147
d
= 5E53
h
Encoder/feedback system: SSI encoder
Selection list
(Lenze setting printed in bold)
Info
0 Binary code
1 Gray code
2 Position Gray
From version 14.00.00
, SSI encoders are supported which
transmit the position data with Gray coding and the
status bits in binary format.
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00430 | LS_MultiEncoder: Max. initialization time
Data type: UNSIGNED_16
Index: 24145
d
= 5E51
h
From version 12.00.00
Encoder/feedback system: sin/cos absolute value encoder with HIPERFACE® protocol
Setting range
(min. value | unit | max. value)
500
ms
20000
Subcodes
Lenze setting
Info
C00430/1
1500 ms
Maximum time required by the encoder to respond to
the read request of the controller.
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1