C00637 | l_nset_1: output blocking zones, C00638 | l_nset_1: output ramp rounding, C00639 | l_nset_1: output additional value – Lenze 8400 TopLine User Manual
Page 1039: C00640 | l_nset_1: nnout_a, C00643 | resp. to pli monitoring, C00643/1, 17 parameter reference
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
1039
17
Parameter reference
17.2
Parameter list | C00637
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00637
C00638
C00639
C00640
C00643
Parameter | Name:
C00637 | L_NSet_1: Output blocking zones
Data type: INTEGER_16
Index: 23938
d
= 5D82
h
FB: Speed setpoint is displayed after being processed by blocking zone function
Display range
(min. value | unit | max. value)
-199.99
%
199.99
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00638 | L_NSet_1: Output ramp rounding
Data type: INTEGER_16
Index: 23937
d
= 5D81
h
FB: Speed setpoint is displayed after being processed by PT1 filter function
Display range
(min. value | unit | max. value)
-199.99
%
199.99
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00639 | L_NSet_1: Output additional value
Data type: INTEGER_16
Index: 23936
d
= 5D80
h
FB: Additional speed setpoint is displayed after being processed by the ramp generator
Display range
(min. value | unit | max. value)
-199.99
%
199.99
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00640 | L_NSet_1: nNOut_a
Data type: INTEGER_16
Index: 23935
d
= 5D7F
h
FB: Display of the generated main speed setpoint at the output nNOut_a
Display range
(min. value | unit | max. value)
-199.99
%
199.99
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00643 | Resp. to PLI monitoring
Data type: UNSIGNED_8
Index: 23932
d
= 5D7C
h
Selection list
0 No Reaction
1 Fault
3 TroubleQuickStop
4 WarningLocked
5 Warning
6 Information
Subcodes
Lenze setting
Info
C00643/1
1: Fault
Response to PLI monitoring
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1