C02812 | tp: position offset, C02813 | tp: pos. window start, C02812/3 – Lenze 8400 TopLine User Manual
Page 1277: C02813/1, C02813/x, C02812/8, C02813/4, C02812/9, C02813/5, And w
![background image](/manuals/566308/1277/background.png)
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
1277
17
Parameter reference
17.2
Parameter list | C02812
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02812
C02813
Parameter | Name:
C02812 | TP: Position offset
Data type: INTEGER_32
Index: 21763
d
= 5503
h
Setting range
(min. value | unit | max. value)
-214748.3647
units
214748.3647
Subcodes
Lenze setting
Info
C02812/1
0.0000 units
Reserved
C02812/2
0.0000 units
Reserved
C02812/3
0.0000 units
TPDigIn3: Pos offset
C02812/4
0.0000 units
TPDigIn4: Pos offset
C02812/5
0.0000 units
TPDigIn5: Pos offset
C02812/6
0.0000 units
TPDigIn6: Pos offset
C02812/7
0.0000 units
TPDigIn7: Pos offset
C02812/8
0.0000 units
TPEncoderZTrack: Pos offset
•
From version 12.00.00
C02812/9
0.0000 units
TPResolverZTrack: Pos offset
•
From version 12.00.00
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 10000
Parameter | Name:
C02813 | TP: Pos. window start
Data type: INTEGER_32
Index: 21762
d
= 5502
h
Setting range
(min. value | unit | max. value)
-214748.3647
units
214748.3647
Subcodes
Lenze setting
Info
C02813/1
-214748.3647 units
TPDigIn3: Window start
C02813/2
-214748.3647 units
TPDigIn4: Window start
C02813/3
-214748.3647 units
TPDigIn5: Window start
C02813/4
-214748.3647 units
TPEncoderZTrack: Window start
•
From version 12.00.00
C02813/5
-214748.3647 units
TPResolverZTrack: Window start
•
From version 12.00.00
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 10000