7i/o terminals – Lenze 8400 TopLine User Manual
Page 414
7
I/O terminals
7.4
Touch probe detection
414
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Short overview of the relevant parameters:
Edge selection
Select which edge the corresponding input is to respond to.
• In the case of signal sources DI3 ... DI5, the edge sensitivity can also be dynamically changed via
inputs at the
SB.
Sensor delay
This setting serves to compensate for a sensor delay of the touch probe sensor, if any.
• Typical values for laser photoelectric barriers are e.g. 300 μs.
• Delay of the digital inputs for the 8400 device series:
• 5 μs for a rising edge
• 25 μs for a falling edge
• Internal automatic compensation for device-internal signal delay due to encoder zero pulse.
Pos Offset
Use this setting to add an offset to the position value measured by touch probe. This may be
required if the touch probe sensor has assumed a disadvantageous position on the machine. By
adding an offset the touch probe sensor can be moved to a position which is more convenient to the
application.
The offset value given in [units] is added to the TP position value which depends on the position
source selected in
. The offset value influences the display of the TP position (
home position values internally derived from the touch probe and the respective output
dnTpDigInX_Position_p at the SB
. For this purpose, the offset value is converted
internally from [units] to [increments].
Parameter
Info
Lenze setting
Value Unit
TPDigIn3 ... TPDigIn7: Edge selection
0: Off
TPDigIn3 ... TPDigIn7: Sensor delay
0 μs
TPDigIn3 ... TPDigIn7: Pos Offset
0.0000 units
TPDigIn3 ... TPDigIn5: Window start
-214748.3647 units
TPDigIn3 ... TPDigIn5: Window end
214748.3647 units
TPDigIn3 ... TPDigIn7: Position source
0: Position encoder actual value
TPDigIn3 ... TPDigIn7: Signal counter
-
TPDigIn3 ... TPDigIn7: TP position
- units
Highlighted in grey = display parameter
Position
t
Offset
C02817/x
C02812/x
LS_TouchProbe.dnTPDigInX_Position_p
LS_MotorInterface.dnMotorPosAct_p
TP position
TP signal