C00417 | deactivate resolver error comp, C00420 | number of encoder increments, C00421 | ls_multiencoder: supply voltage – Lenze 8400 TopLine User Manual
Page 970: C00420/1, C00420, C00417, C00421, C00420/3, Pply voltage, R in
17
Parameter reference
17.2
Parameter list | C00417
970
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00417
C00420
C00421
Parameter | Name:
C00417 | Deactivate resolver error comp.
Data type: UNSIGNED_8
Index: 24158
d
= 5E5E
h
Encoder/feedback system: Resolver
Selection list
(Lenze setting printed in bold)
0 Resolver error comp. act.
1 Resolver error comp. deact.
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00420 | Number of encoder increments
Data type: UNSIGNED_16
Index: 24155
d
= 5E5B
h
Indication of the encoder constant
Encoder/feedback system: Multi-Encoder
Setting range
(min. value | unit | max. value)
1
Incr./rev.
32767
Subcodes
Lenze setting
Info
C00420/1
128 incr./rev.
FreqIn12: Encoder increment
C00420/2
128 incr./rev.
FreqIn67: Encoder increment
C00420/3
512 incr./rev.
: Encoder increment
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00421 | LS_MultiEncoder: Supply voltage
Data type: UNSIGNED_16
Index: 24154
d
= 5E5A
h
Stop!
Before connecting an encoder, make sure that the encoder supply voltage is set correctly!
If the set supply voltage exceeds the permissible supply voltage of the connected encoder, the encoder may be
destroyed!
Encoder/feedback system: Multi-Encoder
Setting range
(min. value | unit | max. value)
Lenze setting
5.0
V
12.0 5.0 V
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 10