19.1.158.11 Action type "Time waiting"
For inserting waiting times into the program flow, 8 actions of "Time waiting" are available. The
sequence step will only be processed after a waiting time has elapsed or when a selectable
sequencer input has a certain bit state ("0" or "1").
Action call (entry in the sequence table)
with action number xxx = 001 ... 008
Parameter
The available actions 1 ... 8 are represented via the subcodes 1 ... 8.
Parameter
Possible settings
Info
0.000
s
2127480.000 Waiting act. n: Waiting time
• Initialisation: 1.000 s
Waiting act. n: Input for "Next"
0 Input deactivated
"Time waiting": Sequence step will
only be processed after the set
waiting time has elapsed.
1 Sequencer input 1
(Bit 0 of wDigitalInputs)
"Wait for level": Sequence step will
only be processed when the selected
sequencer input has the polarity set
Note!
With a waiting time set to > 0 s,
however, the sequence step will be
processed after the set waiting time
has elapsed at the latest.
2 Sequencer input 2
(Bit 1 of wDigitalInputs)
... ...
16 Sequencer input 16
(Bit 15 of wDigitalInputs)
Waiting act. n: Polarity input
• State of the selected sequencer
input required for processing the
sequence step.
0 Condition is bit state "0"
1 Condition is bit state "1"
7 x x x