4device control (dctrl) – Lenze 8400 TopLine User Manual
Page 102
4
Device control (DCTRL)
4.1
Device commands (C00002/x)
102
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Activate device command
When an online connection has been established, simply use the »Engineer« to activate a device
command by selecting the corresponding option from the Parameters tab in
("0: off" or
"1: On / start").
• Alternatively, the device command can also be activated via e.g. keypad or through a master
control by writing to
.
• Some of the frequently used device commands (such as "Save parameter set") can also be
executed via the Toolbar icons of the »Engineer« when an online connection has been
established:
Icon
Function
Enable controller
Inhibit controller
Save parameter set (for 8400: Save all parameter sets)
Note!
Device commands that can be executed via the Toolbar of the »Engineer« always affect
the element currently selected in the Project view including all subelements!
• If no controller but a system module is selected in the Project view, the corresponding
device command will be activated in all lower-level controllers having an online
connection with the »Engineer«.
Before the desired action is carried out, a confirmation prompt appears first, asking
whether the action is really to be carried out.