C02840 | countinx: parameter, C02841 | countinx: counter content, C02842 | freqinxx: offset – Lenze 8400 TopLine User Manual
Page 1281: C02842/1, C02842/2, C02840/1, C02840/2, C02841/1, C02840/3, C02840/4
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
1281
17
Parameter reference
17.2
Parameter list | C02840
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02840
C02841
C02842
Parameter | Name:
C02840 | CountInx: Parameter
Data type: UNSIGNED_32
Index: 21735
d
= 54E7
h
Starting and comparison values for digital count inputs
Setting range
(min. value | unit | max. value)
0
Incr.
2147483647
Subcodes
Lenze setting
Info
C02840/1
0 incr.
CountIn1: Starting value
C02840/2
65535 incr.
CountIn1: Comparison value
C02840/3
0 incr.
CountIn6: Starting value
C02840/4
65535 incr.
CountIn6: Comparison value
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C02841 | CountInx: Counter content
Data type: UNSIGNED_32
Index: 21734
d
= 54E6
h
Display of the current counter content of the digital count inputs
Display range
(min. value | unit | max. value)
0
Incr.
2147483647
Subcodes
Info
C02841/1
CountIn1: Counter content
C02841/2
CountIn6: Counter content
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C02842 | FreqInxx: Offset
Data type: INTEGER_16
Index: 21733
d
= 54E5
h
Offset for digital frequency inputs
Using DI1(6) and DI2(7) as frequency inputs
Setting range
(min. value | unit | max. value)
-199.99
%
199.99
Subcodes
Lenze setting
Info
C02842/1
0.00 %
FreqIn12: Offset
C02842/2
0.00 %
FreqIn67: Offset
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100