C00407 | lp_canin mapping, C00408 | lp_canin mapping selection, C00408/1 – Lenze 8400 TopLine User Manual
Page 967: C00407/1, C00407/2, C00408/2, C00407/3, C00407/4, C00408/3, C00407/5
![background image](/manuals/566308/967/background.png)
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
967
17
Parameter reference
17.2
Parameter list | C00407
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00407
C00408
Parameter | Name:
C00407 | LP_CanIn Mapping
Data type: UNSIGNED_32
Index: 24168
d
= 5E68
h
From version 12.00.00
Mapping for port blocks LP_CanIn1...4
• These settings are ORed with the mapping settings for the single words in
.
Setting range
(min. value | unit | max. value)
0
4294967295
Subcodes
Lenze setting
Info
C00407/1
0
:dwIn12 MapVal
C00407/2
0
:dwIn34 MapVal
C00407/3
0
:dwIn12 MapVal
C00407/4
0
:dwIn34 MapVal
C00407/5
0
:dwIn12 MapVal
C00407/6
0
:dwIn34 MapVal
C00407/7
0
:dwIn12 MapVal
•
From version 15.00.00
C00407/8
0
:dwIn34 MapVal
•
From version 15.00.00
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00408 | LP_CanIn mapping selection
Data type: UNSIGNED_8
Index: 24167
d
= 5E67
h
Selection of the mapping source for port blocks LP_CanIn1...4
Selection list
Info
0 CanIn
CanIn
1 Par.C409|C407
Mapping configured in
Subcodes
Lenze setting
Info
C00408/1
0: CanIn
Mapping selection LP_CanIn1
C00408/2
0: CanIn
Mapping selection LP_CanIn2
C00408/3
0: CanIn
Mapping selection LP_CanIn3
C00408/4
0: CanIn
Mapping selection LP_CanIn4
•
From version 15.00.00
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1