C00583 | resp. to motor temperature kty, C00585 | resp. to motor overtemp. ptc, C00586 | resp. to open circuit htl encoder – Lenze 8400 TopLine User Manual
Page 1014: C00585, Is activated, Tting, Fault"), mo, C00586, Deactivate the monitoring, C00583/1
![background image](/manuals/566308/1014/background.png)
17
Parameter reference
17.2
Parameter list | C00583
1014
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00583
C00585
C00586
Parameter | Name:
C00583 | Resp. to motor temperature KTY
Data type: UNSIGNED_8
Index: 23992
d
= 5DB8
h
Response to motor overtemperature
• The motor temperature is measured via the resolver or encoder cable.
Encoder/feedback system: Motor temperature monitoring (KTY)
Selection list
0 No Reaction
1 Fault
3 TroubleQuickStop
4 WarningLocked
5 Warning
6 Information
Subcodes
Lenze setting
Info
C00583/1
1: Fault
Resp. to motor overtemp. KTY resolver
C00583/2
1: Fault
Resp. to motor overtemp. KTY MultiEncoder
C00583/3
5: Warning
Resp. to motor temp. > C00121 resolver
C00583/4
5: Warning
Resp. to motor temp. > C00121 encoder
C00583/5
1: Fault
Resp. to temp. sensor error KTY resolver
C00583/6
1: Fault
Resp. to temp. sensor error KTY MultiEncoder
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00585 | Resp. to motor overtemp. PTC
Data type: UNSIGNED_8
Index: 23990
d
= 5DB6
h
Response to motor overtemperature
• The motor temperature is measured by means of a PTC thermistor at terminal X106.
Selection list
(Lenze setting printed in bold)
0 No Reaction
1 Fault
5 Warning
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00586 | Resp. to open circuit HTL encoder
Data type: UNSIGNED_8
Index: 23989
d
= 5DB5
h
Response to encoder feedback system failure or encoder feedback system track failure due to open circuit
Selection list
(Lenze setting printed in bold)
0 No Reaction
1 Fault
5 Warning
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1