C00919
C00922
C00925
C00926
C00927
Parameter | Name:
C00919 | Moment of inertia from load
Data type: UNSIGNED_32
Index: 23656
d
= 5C68
h
From version 12.00.00
In order to take account of mass inertias changing during the process (e.g. reels) when optimising the response to
setpoint changes, the maximum value of the changing moment of inertia must be set here. The process signal
nInertiaAdapt_a of the
SB can then be used in the process to dynamically control what
percentage of it is to be taken into account for the setpoint feedforward control.
Setting range
(min. value | unit | max. value)
0.00
kg cm^2
6000000.00
Subcodes
Lenze setting
Info
C00919/1
0.00 kg cm^2
Load moment of inertia
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00922 | ICM_DiagnosticCounter
Data type: UNSIGNED_16
Index: 23653
d
= 5C65
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C00925 | LS_Resolver: Number of pole pairs
Data type: UNSIGNED_8
Index: 23650
d
= 5C62
h
Setting range
(min. value | unit | max. value)
Lenze setting
1
10 1
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00926 | Pole position
Data type: INTEGER_16
Index: 23649
d
= 5C61
h
Setting range
(min. value | unit | max. value)
-179.9
°
179.9
Subcodes
Lenze setting
Info
C00926/1
-90.0 °
: Pole position
C00926/2
0.0 °
: Pole position
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 10
Parameter | Name:
C00927 | Motor rotor position
Data type: UNSIGNED_16
Index: 23648
d
= 5C60
h
Display range
(min. value | unit | max. value)
0
2047
Read access Write access CINH PLC STOP No transfer COM MOT