C00385 | can node addr. heartbeat producer, C00386 | can heartbeat consumertime, C00387 | can-gatewayaddr – Lenze 8400 TopLine User Manual
Page 965: C00386/1...n, C00385/1...n, Cer in, C00385/1, C00386/1, C00385/x, C00386/x
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
965
17
Parameter reference
17.2
Parameter list | C00385
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00385
C00386
C00387
Parameter | Name:
C00385 | CAN node addr. HeartBeat producer
Data type: UNSIGNED_8
Index: 24190
d
= 5E7E
h
The subcodes represent the nodes to be monitored by heartbeat.
Setting range
(min. value | unit | max. value)
0
127
Subcodes
Lenze setting
Info
C00385/1
0
CAN node address HeartBeat producer 1 ... 15
C00385/...
C00385/15
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00386 | CAN HeartBeat ConsumerTime
Data type: UNSIGNED_16
Index: 24189
d
= 5E7D
h
The subcodes represent the nodes to be monitored by heartbeat.
Setting range
(min. value | unit | max. value)
0
ms
60000
Subcodes
Lenze setting
Info
C00386/1
0 ms
ConsumerTime HeartBeat producer 1 ... 15
C00386/...
C00386/15
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00387 | CAN-GatewayAddr
Data type: UNSIGNED_8
Index: 24188
d
= 5E7C
h
From version 12.00.00
Setting range
(min. value | unit | max. value)
0
127
Subcodes
Lenze setting
Info
C00387/1
0
CAN_Gateway: Addr.
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1