19 function library – Lenze 8400 TopLine User Manual
Page 1433
![background image](/manuals/566308/1433/background.png)
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
1433
19
Function library
19.1
Function blocks
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Parameter
bNegOverrange
BOOL
Monitoring of lower home position
TRUE Lower home position (
) reached.
nVAdditive_a
INT
Material speed caused by the dancer motion
• Scaling: 16384 ≡ Maximum material speed (wVMax)
nVOut_a
INT
Current circumferential speed of the reel when the dancer hub is entered
• Scaling: 16384 ≡ Maximum material speed (wVMax)
nMAdditive_a
INT
Additional torque for damping the dancer position control
• Scaling: 16384 ≡ 100 %
Parameter
Possible settings
Info
0
ms
1000 TConst
• Time constant for filtering the
actual position value.
• Lenze setting: 10 ms
%
Upper limit position
• Lenze setting: 100.00 %
%
Lower limit position
• Lenze setting: -100.00 %
mm
dwLength
• Storage volumen of the dancer
(dancer hub).
• Lenze setting:
%
Upper home position
• Lenze setting: 90.00 %
%
Lower home position
• Lenze setting: -90.00 %
%
nWindowSetPos
• Tolerance zone for monitoring the
dancer position.
• Lenze setting: 10.00 %
s
wDelayTime
• Delay time for monitoring the
dancer position.
• Lenze setting: 0.100 s
ms
wTConstVAdd
• Time constant for filtering the
additional speed.
• Lenze setting: 10 ms
%
nDeadBand
• Dead band area for feedforward
control torque (nMAdditive_a).
• Lenze setting: 1.00 %
wDamping
• Damping factor for feedforward
control torque (nMAdditive_a).
• Lenze setting: 0.00
Identifier
Data type
Value/meaning