C00091 | motor cosine phi, C00092 | motor magnetising inductance, C00093 | power section identification – Lenze 8400 TopLine User Manual
Page 906: C00095 | motor magnetising current, C00097 | rated motor torque, C00091, C00095, C00092, Ing inductance, Moto
17
Parameter reference
17.2
Parameter list | C00091
906
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00091
C00092
C00093
C00095
C00097
Parameter | Name:
C00091 | Motor cosine phi
Data type: UNSIGNED_8
Index: 24484
d
= 5FA4
h
This value can be obtained from the motor nameplate. After the motor to be used has been selected from the motor
catalogue, the suitable value can be entered automatically.
Setting range
(min. value | unit | max. value)
Lenze setting
0.40
1.00 0.85
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00092 | Motor magnetising inductance
Data type: UNSIGNED_16
Index: 24483
d
= 5FA3
h
After the motor to be used has been selected from the motor catalogue, the suitable value can be entered
automatically. An automatic detection via the motor parameter identification is possible as well.
Setting range
(min. value | unit | max. value)
Lenze setting
0.0
mH
6500.0 81.0 mH
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 10
Parameter | Name:
C00093 | Power section identification
Data type: UNSIGNED_16
Index: 24482
d
= 5FA2
h
Display of the identification of the detected power section of the controller
Display range
(min. value | unit | max. value)
0
65535
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00095 | Motor magnetising current
Data type: UNSIGNED_16
Index: 24480
d
= 5FA0
h
After the motor to be used has been selected from the motor catalogue, the suitable value can be entered
automatically. An automatic detection via the motor parameter identification is possible as well.
Setting range
(min. value | unit | max. value)
Lenze setting
0.00
A
320.00 8.50 A
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00097 | Rated motor torque
Data type: UNSIGNED_32
Index: 24478
d
= 5F9E
h
Display of the rated motor torque
• The value displayed here is calculated from different parameters, e.g. the maximum current set in
Display range
(min. value | unit | max. value)
0.00
Nm
100000.00
Read access Write access CINH PLC STOP No transfer COM MOT