C02593 | holding brake: activation time, C02593/1, C02593/2 – Lenze 8400 TopLine User Manual
Page 1272: 17 parameter reference
17
Parameter reference
17.2
Parameter list | C02593
1272
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02593
Parameter | Name:
C02593 | Holding brake: Activation time
Data type: UNSIGNED_32
Index: 21982
d
= 55DE
h
Time parameter for the delay of trigger signals of the holding brake control
Setting range
(min. value | unit | max. value)
0.000
s
3600.000
Subcodes
Lenze setting
Info
C02593/1
0.000 s
Holding brake: Actual value monitoring
• Time in which the actual value is supposed to reach
the threshold for closing the brake if the setpoint has
already reached the threshold.
• Time > 0 s: If the actual speed value has not reached
the threshold within the time for brake application,
the holding brake is applied by control.
• Time = 0 s: The brake is only applied by control when
the actual speed has reached the application
threshold.
C02593/2
0.000 s
Holding brake: Application delay
• Time by which the control process for holding brake
application is delayed. The time expires when the
speed setpoint has reached the switching threshold
for application.
• With positioning processes, a continuous application
and release of the holding brake can thus be
suppressed for the set time.
C02593/3
0.000 s
Holding brake: Reserved
C02593/4
0.000 s
Holding brake: Reserved
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1000