17 parameter reference – Lenze 8400 TopLine User Manual
Page 1320
17
Parameter reference
17.6
Table of attributes
1320
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
VFC: Voltage interpol. point n
Linear value
23607
5C37
A
11
UNSIGNED_16
100
Motorparameter
Linear value
23606
5C36
A
1
UNSIGNED_8
1
VFC: V/f +encoder limitation
Linear value
23604
5C34
A
2
UNSIGNED_16
100
VFC: Vp V/f +encoder
Linear value
23603
5C33
E
1
UNSIGNED_16
1000
VFC: Ti V/f +encoder
Linear value
23602
5C32
E
1
UNSIGNED_16
10
VFC-ECO: Vp CosPhi controller
Linear value
23600
5C30
E
1
UNSIGNED_16
1000
VFC-ECO: Ti CosPhi controller
Linear value
23599
5C2F
E
1
UNSIGNED_16
10
VFC-ECO: Minimum voltage V/f
Linear value
23598
5C2E
E
1
INTEGER_16
100
VFC-ECO: Voltage reduction
Linear value
23597
5C2D
E
1
INTEGER_16
1
Cosine phi
Linear value
23596
5C2C
A
2
INTEGER_16
100
Output power
Linear value
23595
5C2B
A
2
INTEGER_32
1000
Energy display
Linear value
23594
5C2A
A
2
INTEGER_32
100
VFC-ECO: Voltage reduction ramp
Linear value
23593
5C29
E
1
UNSIGNED_8
10
Delay
Linear value
23592
5C28
A
1
UNSIGNED_16
1
SLVC: Field current controller gain
Linear value
23590
5C26
E
1
INTEGER_16
100
SLVC: Cross current controller gain
Linear value
23589
5C25
E
1
INTEGER_16
100
Inverter motor brake: nAdd
Linear value
23588
5C24
E
1
INTEGER_16
1
Inverter motor brake: PT1 filter time
Linear value
23587
5C23
E
1
INTEGER_16
10
Flying restart fct.: Activate
Selection list
23585
5C21
E
1
UNSIGNED_8
1 CINH
Flying restart fct.: Process
Selection list
23584
5C20
E
1
UNSIGNED_16
1
Flying restart fct.: Start frequency
Linear value
23583
5C1F
E
1
INTEGER_16
1
Flying restart fct: Int. time
Linear value
23582
5C1E
E
1
UNSIGNED_16
10
Flying restart fct.: Current
Linear value
23581
5C1D
E
1
INTEGER_16
100
SLPSM: Controlled current setpoint
Linear value
23580
5C1C
A
2
UNSIGNED_16
100
SLPSM: Switching speed
Linear value
23579
5C1B
A
2
INTEGER_16
100
SLPSM: Filter cutoff frequency
Linear value
23578
5C1A
E
1
INTEGER_16
100
SLPSM: Filter time rotor position
Linear value
23577
5C19
A
2
INTEGER_16
10
SLPSM: PLL gain
Linear value
23576
5C18
E
1
INTEGER_16
1
MCTRL: Status
Bit coded
23575
5C17
E
1
UNSIGNED_16
1
Manual entry of motor type
Selection list
23574
5C16
A
1
UNSIGNED_8
1
L_ArithmetikPhi 1-3: Function
Selection list
23565
5C0D
A
3
UNSIGNED_8
1
L_ArithmetikPhi 4-6: Function
Selection list
23564
5C0C
A
3
UNSIGNED_8
1
L_PhiDiv: byDivision
Linear value
23563
5C0B
A
1
INTEGER_8
1
L_Odometer_1: Memory length
Selection list
23555
5C03
E
1
UNSIGNED_8
1
L_Odometer_1: Memory type
Selection list
23554
5C02
E
1
UNSIGNED_8
1
L_Odometer_1: Input selection
Selection list
23553
5C01
E
1
UNSIGNED_8
1
L_Odometer_1: Edge selection
Selection list
23552
5C00
E
1
UNSIGNED_8
1
L_Curve_2: Selected curve type
Selection list
23550
5BFE
A
1
UNSIGNED_8
1
L_Curve_2: Input limitation
Linear value
23549
5BFD
A
2
INTEGER_16
100
L_Curve_2: Table X-values
Linear value
23547
5BFB
A
32
INTEGER_16
1
L_Curve_2: Table Y-values
Linear value
23546
5BFA
A
32
INTEGER_16
1
L_Curve_3: Selected curve type
Selection list
23545
5BF9
A
1
UNSIGNED_8
1
L_Curve_3: Input limitation
Linear value
23544
5BF8
A
2
INTEGER_16
100
L_Curve_3: Table X-values
Linear value
23542
5BF6
A
32
INTEGER_16
1
L_Curve_3: Table Y-values
Linear value
23541
5BF5
A
32
INTEGER_16
1
L_Curve_3: SelectCurve
Selection list
23540
5BF4
A
1
UNSIGNED_16
1
L_SRFG_1..2 linear ramp time
Linear value
23535
5BEF
A
2
UNSIGNED_32
1000
L_SRFG_1..2 S-ramp time
Linear value
23534
5BEE
A
2
UNSIGNED_32
1000
L_SRFG_1..2 limitations of output values
Linear value
23533
5BED
A
4
INTEGER_16
100
L_ConvAP 1-3: numerator/denominator
Linear value
23530
5BEA
A
6
INTEGER_16
1
Code
Name
Type
Index
Data
dec
hex
DS
DA
DT
Factor
CINH