C01000 | mctrl: status, C01001 | manual entry of motor type, C01000 – Lenze 8400 TopLine User Manual
Page 1138: Displays the set mot, C01001/1, 17 parameter reference
17
Parameter reference
17.2
Parameter list | C01000
1138
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01000
C01001
Parameter | Name:
C01000 | MCTRL: Status
Data type: UNSIGNED_16
Index: 23575
d
= 5C17
h
Display area
(min. hex value | max. hex value)
0x0000
0xFFFF
Value is bit-coded:
Info
Bit 0 SLPSM: Speed closed-loop control
1 ≡ The sensorless control for synchronous motors is in
the closed-loop controlled operation (|n
Setpoint
| >
n
C00996
).
Sensorless control for synchronous motors (SLPSM)
Bit 1 SLPSM: Speed open-loop control
From version 12.00.00
1 ≡ The sensorless control for synchronous motors is in
the open-loop controlled operation (|n
Setpoint
| > n
C00996
).
Sensorless control for synchronous motors (SLPSM)
Bit 2 Motor ASM
From version 12.00.00
1 ≡ Set motor type is "Asynchronous motor"
Bit 3 Motor PSM
From version 12.00.00
1 ≡ Set motor type is "Synchronous motor"
Bit 4 Encoder open circuit: V/f linear active
From version 15.00.00
1 ≡ Due to an encoder open circuit, it has been internally
switched to the encoderless V/f characteristic control to
avoid impermissible motor movements.
Bit 5
Reserved
Bit 6
Reserved
Bit 7
Reserved
Bit 8
Reserved
Bit 9
Reserved
Bit 10
Reserved
Bit 11
Reserved
Bit 12
Reserved
Bit 13
Reserved
Bit 14
Reserved
Bit 15
Reserved
Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C01001 | Manual entry of motor type
Data type: UNSIGNED_8
Index: 23574
d
= 5C16
h
From version 14.00.00
Selection list
0 Automatic
1 ASM
2 PSM
Subcodes
Lenze setting
Info
C01001/1
0: Automatic
Manual entry of motor type
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1