9basic drive functions (mck) – Lenze 8400 TopLine User Manual
Page 561
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
561
9
Basic drive functions (MCK)
9.2
Internal interfaces | System block "LS_MotionControlKernel"
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
MCK control word 2 (wMotionCtrl2)
Tip!
Travel requests/profiles can also be started while the drive is running. The drive does not
need to be at standstill.
Bit
Designation
Description
16 PosExecute
"01" ≡ Start travelling
17 PosFinishTarget
"01" ≡ Complete cancelled profile
18 PosDisable
FollowProfile
"1" ≡ Do not travel sequence profile
19 PosStop
"1" ≡ Cancel travelling
From version 02.00.00
, more travel requests will be inhibited ("PosExecute" will be
blocked).
20
...
23
PosModeBit0
...
PosModeBit3
Positioning mode
Bit 3
Bit 2
Bit 1
Bit 0
0
0
0
0
Absolute (shortest path)
0
0
0
1
Continuous
0
0
1
0
Relative
0
0
1
1
absolute (Cw)
0
1
0
0
absolute (Ccw)
0
1
0
1
Absolute (shortest path) to TP
1
0
0
0
Continuous to TP
1
0
0
1
Relative to TP
1
0
1
0
Absolute (Cw) on TP
1
0
1
1
Absolute (Ccw) on TP
1
1
0
0
All other possible settings are reserved for future extensions!
24
...
31
ProfileNo_Bit0
...
ProfileNo_Bit7
Profile
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Profile 0
0
0
0
0
0
0
0
0
Profile 1
0
0
0
0
0
0
0
1
Profile 2
0
0
0
0
0
0
1
0
...
...
Profile 15
0
0
0
0
1
1
1
1
All other possible settings are reserved for future extensions!
Note!
The profile 0 is no valid profile for the "
" operating mode.
If a driving request with an invalid profile number is started, the response set in
occurs (Lenze setting: "WarningLocked").