C01304 | profile data: deceleration, C01305 | profile data: final speed, C01306 | profile data: s-ramp time – Lenze 8400 TopLine User Manual
Page 1201: C01304/x, C01306/x, C01305/x, C01304/1, C01306/1, C01305/1, 17 parameter reference
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
1201
17
Parameter reference
17.2
Parameter list | C01304
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01304
C01305
C01306
Parameter | Name:
C01304 | Profile data: Deceleration
Data type: INTEGER_32
Index: 23271
d
= 5AE7
h
Selection of the decelerations for profiles 1 ... 15
Setting range
(min. value | unit | max. value)
-214748.3647
unit/s2
214748.3647
Subcodes
Lenze setting
Info
C01304/1
720.0000 unit/s2
Profiles 1 ... 15: Deceleration
C01304/...
C01304/15
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 10000
Parameter | Name:
C01305 | Profile data: Final speed
Data type: INTEGER_32
Index: 23270
d
= 5AE6
h
Selection of the final speeds for profiles 1 ... 15
• For profile linkage with overchange.
Setting range
(min. value | unit | max. value)
-214748.3647
unit/s
214748.3647
Subcodes
Lenze setting
Info
C01305/1
0.0000 unit/s
Profiles 1 ... 15: Final speed
C01305/...
C01305/15
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 10000
Parameter | Name:
C01306 | Profile data: S-ramp time
Data type: UNSIGNED_16
Index: 23269
d
= 5AE5
h
Selection of the S-ramp times for profiles 1 ... 15
• The maximum S-ramp time is the time in which the maximum acceleration or the maximum deceleration is
reached along a ramp (jerk limitation).
Setting range
(min. value | unit | max. value)
0.000
s
10.000
Subcodes
Lenze setting
Info
C01306/1
0.000 s
Profiles 1 ... 15: S-ramp time
C01306/...
C01306/15
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1000