C00431 | ls_multiencoder: bfail selection, N in, C00431/1 – Lenze 8400 TopLine User Manual
Page 975: 17 parameter reference
![background image](/manuals/566308/975/background.png)
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
975
17
Parameter reference
17.2
Parameter list | C00431
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00431
Parameter | Name:
C00431 | LS_MultiEncoder: bFail selection
Data type: UNSIGNED_16
Index: 24144
d
= 5E50
h
From version 13.00.00
Bit coded setting which events cause the bFail output to be set.
Setting range
(min. hex value | max. hex value)
0x0000
0xFFFF
Value is bit-coded:
Info
Bit 0 Encoder open circuit
Bit 1 KTY open circuit
Bit 2 Position beyond C1112/2..3
Bit 3 Angular drift error
Bit 4 Communication error
Bit 5 Hiperface position invalid
From version 14.00.00
Bit 6 Linear data overflow SSI
From version 14.00.00
Bit 7 Max. encoder speed
From version 14.00.00
Bit 8 Hiperface init active
Bit 9
Reserved
Bit 10
Reserved
Bit 11
Reserved
Bit 12
Reserved
Bit 13
Reserved
Bit 14
Reserved
Bit 15
Reserved
Subcodes
Lenze setting
Info
C00431/1
0x001D
: bFail selection
Read access Write access CINH PLC STOP No transfer COM MOT