C01237
C01238
C01239
Parameter | Name:
C01237 | MCK: Acceleration follower
Data type: INTEGER_32
Index: 23338
d
= 5B2A
h
Accelerations for position follower
Setting range
(min. value | unit | max. value)
-214748.3647
units/s2
214748.3647
Subcodes
Lenze setting
Info
C01237/1
720.0000 units/s2
Pos follower: Sync. accel.
• Acceleration for ramp-up to synchronisation speed.
C01237/2
720.0000 units/s2
Pos follower: Sync. decel.
• Deceleration for synchronisation speed ramp-down
to standstill (to the setpoint position of the master).
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 10000
Parameter | Name:
C01238 | MCK: S-ramp time follower
Data type: UNSIGNED_16
Index: 23337
d
= 5B29
h
S-ramp times for position follower
• Setting "0 s" ≡ no rounding
Setting range
(min. value | unit | max. value)
0.000
s
10.000
Subcodes
Lenze setting
Info
C01238/1
0.000 s
Pos follower: Sync. S-ramp time
• S-ramp time for the synchronisation speed ramps.
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1000
Parameter | Name:
C01239 | Setpoint holding
Data type: UNSIGNED_32
Index: 23336
d
= 5B28
h
From version 12.00.00
Setpoint holding for bus runtime compensation
Setting range
(min. value | unit | max. value)
Lenze setting
0
ms
32 0 ms
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1