17 parameter reference – Lenze 8400 TopLine User Manual
Page 1033
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
1033
17
Parameter reference
17.2
Parameter list | C00621
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00621/122
0: Not connected
: bReadWrite
Read/write request 6: Selection of reading/writing
C00621/123
0: Not connected
: bExecute
Writing the parameter list: Activate
C00621/124
0: Not connected
: bSelectWriteValue_1
Writing to parameter list: Selection of value set - 1
C00621/125
0: Not connected
: bSelectWriteValue_2
Writing to parameter list: Selection of value set - 2
C00621/126
0: Not connected
Reset CAN node
C00621/127
0: Not connected
: bReInitCAN
Reinitialise CAN interface
C00621/128
0: Not connected
: bPosIn12_Load
Frequency input DI1/DI2: Load angle integrator with
starting value and reset status signal
C00621/147
0: Not connected
: bDisableTPDigIn3
TP input DI3: Disable TP function dynamically
C00621/148
0: Not connected
: bDisableTPDigIn4
TP input DI4: Disable TP function dynamically
C00621/149
0: Not connected
: bDisableTPDigIn5
TP input DI5: Disable TP function dynamically
C00621/150
0: Not connected
: bDisableTPDigIn6
TP input DI6: Disable TP function dynamically
C00621/151
0: Not connected
: bDisableTPDigIn7
TP input DI7: Disable TP function dynamically
C00621/152
0: Not connected
: bDisableTPDigIn3_Rising
TP input DI3: Disable recognition of rising edges
dynamically
C00621/153
0: Not connected
: bDisableTPDigIn3_Falling
TP input DI3: Disable recognition of falling edges
dynamically
C00621/154
0: Not connected
: bDisableTPDigIn4_Rising
TP input DI4: Disable recognition of rising edges
dynamically
C00621/155
0: Not connected
: bDisableTPDigIn4_Falling
TP input DI4: Disable recognition of falling edges
dynamically
C00621/156
0: Not connected
: bDisableTPDigIn5_Rising
TP input DI5: Disable recognition of rising edges
dynamically
C00621/157
0: Not connected
: bDisableTPDigIn5_Falling
TP input DI5: Disable recognition of falling edges
dynamically
C00621/158
0: Not connected
: bDisableTPDigIn3Window
TP input DI3: Enable acceptance window
C00621/159
0: Not connected
: bDisableTPDigIn4Window
TP input DI4: Enable acceptance window
C00621/160
0: Not connected
: bDisableTPDigIn5Window
TP input DI5: Enable acceptance window
C00621/161
0: Not connected
: bSetFail
Set IO axis bus into the "error" status / IO data exchange
C00621/162
0: Not connected
IO axis bus: Reset "error" status
Parameter | Name:
C00621 | System connection list: Bool
Data type: UNSIGNED_16
Index: 23954
d
= 5D92
h