C00953 | l_interpolator_1: speed-up, C00959 | l_curve: current output value, 17 parameter reference – Lenze 8400 TopLine User Manual
Page 1127
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
1127
17
Parameter reference
17.2
Parameter list | C00951
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00951
C00952
C00953
C00959
Parameter | Name:
C00951 | L_Interpolator_1: No. of interpolation steps
Data type: UNSIGNED_16
Index: 23624
d
= 5C48
h
FB: No. of interpolation steps
Setting range
(min. value | unit | max. value)
Lenze setting
0
65535 1
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00952 | L_Interpolator_1: Limit value - error cycles
Data type: UNSIGNED_16
Index: 23623
d
= 5C47
h
FB: Limit value for missing data telegrams
Setting range
(min. value | unit | max. value)
Lenze setting
0
65535 5
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00953 | L_Interpolator_1: Speed-up
Data type: UNSIGNED_8
Index: 23622
d
= 5C46
h
FB
: Limitation of the number of correction increments per cycle (speed-up)
Setting range
(min. value | unit | max. value)
Lenze setting
0
100 0
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00959 | L_Curve: Current output value
Data type: INTEGER_16
Index: 23616
d
= 5C40
h
From version 02.00.00
FB
: Display of the current output value nOut_a
Display range
(min. value | unit | max. value)
-199.99
%
199.99
Subcodes
Info
C00959/1
: Current output value
C00959/2
: Current output value
C00959/3
: Current output value
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100