Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
889
17
Parameter reference
17.2
Parameter list | C00010
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00010
C00011
C00012
Parameter | Name:
C00010 | AIN1: Characteristic
Data type: INTEGER_16
Index: 24565
d
= 5FF5
h
Signal adaptation via characteristic
Setting range
(min. value | unit | max. value)
0.00
%
199.99
Subcodes
Lenze setting
Info
C00010/1
0.00 %
AIN1: (+y0) = min
C00010/2
0.00 %
AIN1: (+x0) = Dead band
C00010/3
0.00 %
AIN1: (-y0) = (-min)
C00010/4
0.00 %
AIN1: (-x0) = (-Dead band)
C00010/5
100.00 %
AIN1: (+ymax)
C00010/6
100.00 %
AIN1: (+xmax)
C00010/7
100.00 %
AIN1: (-ymax)
C00010/8
100.00 %
AIN1: (-xmax)
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00011 | Appl.: Reference speed
Data type: UNSIGNED_16
Index: 24564
d
= 5FF4
h
Setting the reference speed
• In the controller, all speed-related signals are processed to one reference variable in percent.
• Set a reference speed here that corresponds to 100 %.
• The frequency that corresponds to the set reference speed is displayed in
Note:
This is not a maximum limitation!
All values in percent in the controller may be in a range of 0 ... 199.99 %.
Setting range
(min. value | unit | max. value)
Lenze setting
50
rpm
60000 1500 rpm
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00012 | Accel. time - main setpoint
Data type: UNSIGNED_32
Index: 24563
d
= 5FF3
h
FB: Acceleration time of the ramp generator for the main speed setpoint
• Generally, this ramp generator is used for all speed-controlled technology applications.
Setting range
(min. value | unit | max. value)
Lenze setting
0.000
s
999.999 2.000 s
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1000