C02862
C02863
C02864
Parameter | Name:
C02862 | Resolver gain
Data type: UNSIGNED_16
Index: 21713
d
= 54D1
h
Encoder/feedback system: Resolver
Setting range
(min. value | unit | max. value)
0.00
%
199.99
Subcodes
Lenze setting
Info
C02862/1
100.00 %
Resolver: sine gain
C02862/2
100.00 %
Resolver: cos gain
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C02863 | Resolver: Phase error
Data type: INTEGER_16
Index: 21712
d
= 54D0
h
Encoder/feedback system: Resolver
Setting range
(min. value | unit | max. value)
Lenze setting
-199.99
%
199.99 0.00 %
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C02864 | MCTRL: Optimisiations
Data type: UNSIGNED_16
Index: 21711
d
= 54CF
h
From version 14.00.00
Activation of special functions of the internal motor control
Setting range
(min. hex value | max. hex value)
0x0000
0xFFFF
Value is bit-coded:
Info
Bit 0 Motor temp. 90° for operation
without KTY
1 ≡ Warm machine. In case the temperature tracking is
not active, a motor temperature of 90 °C is assumed.
Temperature compensation within the motor control
Bit 1 No switch-off of the brake chopper
after 4s
1 ≡ Limitation of the operating time of the brake chopper
(brake transistor) is deactivated.
Braking operation/brake energy management
Bit 2 Brake chopper off in case of trip
0 ≡ No response of the brake chopper in the "Fault"
device status.
1 ≡ In the "Fault" device status, the brake chopper is
permanently switched off without any delay.
Braking operation/brake energy management
Bit 3 Reserved (do not change!)
Bit 4 Motor ident: Switching frequency
8kHz
Switching frequency for motor parameter identification:
0 ≡ 4 kHz
1 ≡ 8 kHz
Preventing a decrease of the switching frequency
Bit 5 Field/field weakening control in
500us
Cycle time for field weakening control:
0 ≡ 1 ms
1 ≡ 500 μs