Id8: speed encoder has not been set [xx.0123.00061, Sd8: encoder angular drift monit. [xx.0123.00062, Oc11: clamp operation active [xx.0123.00071 – Lenze 8400 TopLine User Manual
Page 713: Oc12, Oc12: i2xt brake resistor overload, Oc12: i2xt overload brake resistor, Sd8: encoder angular drift monit, Error m, Xx.0123.00060, Xx.0123.00061
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
713
10
Diagnostics & error management
10.9
Error messages of the operating system
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Id7: Motor control does not match motor data [xx.0123.00060]
Id8: Speed encoder has not been set [xx.0123.00061]
Sd8: Encoder angular drift monit. [xx.0123.00062]
oC12: I2xt overload - brake resistor [xx.0123.00065]
oC11: Clamp operation active [xx.0123.00071]
Response (Lenze setting printed in bold)
Setting:
( Adjustable response)
0: No Reaction 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked 5: Warning 6: Information
Cause
Remedy
At controller enable, the device has detected that the
cannot control the
motor type set.
• Example: Motor nameplate data for an asynchronous
motor have been entered; however, a motor control
type for a synchronous motor is set in
.
Note:
Since the "VFCplus" control types are able to control
every motor to a certain extent, this error message will
never occur here.
Enter correct motor nameplate data and set a matching
motor control type in
:
• Motor nameplate data asynchronous motor motor
control type must be ASM, SLVC or VFCplus servo
control.
• Motor nameplate data synchronous motor motor
control type must be PSM, SLPSM or VFCplus servo
control.
Response (Lenze setting printed in bold)
Setting:
( Adjustable response)
0: No Reaction 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked 5: Warning 6: Information
Cause
Remedy
When being In controller enable status, the device has
detected that a motor control type with feedback has
, but no speed sensor has been set in
Set the speed sensor in
.
Note: The error can only be reset if the settings in
and
match.
Response (Lenze setting printed in bold)
Setting:
( Adjustable response)
0: No Reaction 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked 5: Warning 6: Information
Cause
Remedy
• Encoder signal interferences (EMC).
• Encoder cable interrupted.
• Encoder defective.
• Faulty parameter setting of the encoder.
• Check encoder cable, use shorter encoder cable if
required.
• Check encoder.
• Check parameter setting.
• If required, switch off monitoring (
Response (Lenze setting printed in bold)
0: No Reaction 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked 5: Warning 6: Information
Cause
Remedy
Too frequent and too long braking processes.
Check drive dimensioning.
Response (Lenze setting printed in bold)
0: No Reaction 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked 5: Warning 6: Information
Cause
Remedy
The device indicates that the "CLAMP" overcurrent
limitation has been activated.
• A permanent clamp operation causes an overload
disconnection.
Reduce setpoint generation dynamics or motor load.