C01466 | l_convactpos: tconstvadd, C01467 | l_convactpos: deadband, C01468 | l_convactpos: damping – Lenze 8400 TopLine User Manual
Page 1227: C01469 | l_mfail: vp, 17 parameter reference
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
1227
17
Parameter reference
17.2
Parameter list | C01466
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01466
C01467
C01468
C01469
Parameter | Name:
C01466 | L_ConvActPos: TConstVAdd
Data type: UNSIGNED_16
Index: 23109
d
= 5A45
h
From version 12.00.00
Setting range
(min. value | unit | max. value)
0
ms
1000
Subcodes
Lenze setting
Info
C01466/1
10 ms
: TConstVAdd
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01467 | L_ConvActPos: DeadBand
Data type: INTEGER_16
Index: 23108
d
= 5A44
h
From version 12.00.00
Setting range
(min. value | unit | max. value)
0.00
%
100.00
Subcodes
Lenze setting
Info
C01467/1
1.00 %
: DeadBand
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C01468 | L_ConvActPos: Damping
Data type: UNSIGNED_16
Index: 23107
d
= 5A43
h
From version 12.00.00
Setting range
(min. value | unit | max. value)
0.00
10.00
Subcodes
Lenze setting
Info
C01468/1
0.00
: Damping
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C01469 | L_MFail: Vp
Data type: UNSIGNED_16
Index: 23106
d
= 5A42
h
From version 12.00.00
Setting range
(min. value | unit | max. value)
0.001
31.000
Subcodes
Lenze setting
Info
C01469/1
1.000
: Vp
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1000