C00472 | ls_parfree_a, C00473 | ls_parfree_v, C00472/1 – Lenze 8400 TopLine User Manual
Page 990: 17 parameter reference
![background image](/manuals/566308/990/background.png)
17
Parameter reference
17.2
Parameter list | C00472
990
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00472
C00473
Parameter | Name:
C00472 | LS_ParFree_a
Data type: INTEGER_16
Index: 24103
d
= 5E27
h
SB: Setting of the analog signals to be output
Setting range
(min. value | unit | max. value)
-199.99
%
199.99
Subcodes
Lenze setting
Info
C00472/1
0.00 %
Value for output nPar1_a
C00472/2
0.00 %
Value for output nPar2_a
C00472/3
100.00 %
Value for output nPar3_a
C00472/4
100.00 %
Value for output nPar4_a
C00472/5
0.00 %
Value for output nPar5_a
C00472/6
0.00 %
Value for output nPar6_a
C00472/7
0.00 %
Value for output nPar7_a
C00472/8
0.00 %
Value for output nPar8_a
C00472/9
0.00 %
Value for output nPar9_a
C00472/10
0.00 %
Value for output nPar10_a
C00472/11
0.00 %
Value for output nPar11_a
C00472/12
0.00 %
Value for output nPar12_a
C00472/13
0.00 %
Value for output nPar13_a
C00472/14
0.00 %
Value for output nPar14_a
C00472/15
0.00 %
Value for output nPar15_a
C00472/16
0.00 %
Value for output nPar16_a
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00473 | LS_ParFree_v
Data type: INTEGER_16
Index: 24102
d
= 5E26
h
SB: Setting of the speed signals to be output
Setting range
(min. value | unit | max. value)
-32767
Incr./ms
32767
Subcodes
Lenze setting
Info
C00473/1
0 incr./ms
Values for output nPar1_v ... nPar8_v
C00473/...
C00473/8
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1