35 ls_pulsegenerator, 35 ls_pulsegenerator 5, Ls_pulsegenerator – Lenze 8400 TopLine User Manual
Page 1725: 19 function library
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
1725
19
Function library
19.2
System blocks
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
19.2.35
LS_PulseGenerator
This system block outputs 9 different fixed frequencies and 1 frequency with parameterisable
pulse/dead time.
The SB provides a TRUE signal at the bFirstCycleDone output when the first 1-ms processing cycle is
completed and the time set in 1
has expired. This status signal can e.g. be used for the
delayed enable of peripheral devices or motor control setpoints so that all required initial values are
calculated first after the controller switch-on.
Outputs
Identifier
Data type
Value/meaning
b100Hz
BOOL
Rectangular signal 100 Hz
b10Hz
BOOL
Rectangular signal 10 Hz
b2Hz
BOOL
Rectangular signal 2 Hz
b1Hz
BOOL
Rectangular signal 1 Hz
b1HzFlash
BOOL
80 ms-pulse, repetition rate every second
b2HzFlash
BOOL
80 ms-pulse, repetition rate every 0.5 seconds
bSingleFlash1
BOOL
80 ms pulse, repetition rate every 1.25 seconds
bSingleFlash2
BOOL
80 ms pulse, repetition rate every 3 seconds
bDoubleFlash
BOOL
80 ms-double pulse, repetition rate every 1.25 seconds
bSquareWave
BOOL
Output frequency with pulse/dead time set in
bFirstCycleDone
BOOL
Status signal "First processing cycle completed"
TRUE The first 1-ms processing cycle has been completed and the time set
in
has expired (i.e. all FBs have been called at least once).
E+]
E+]
E+]
E6LQJOH)ODVK
/6B3XOVH*HQHUDWRU
E+]
E+])ODVK
E+])ODVK
& &
+]
E6LQJOH)ODVK
E'RXEOH)ODVK
E6TXDUH:DYH
E)LUVW&\FOH'RQH
&