C00117 | status of brake output bd, C00118 | digoutx: inversion, C00120 | setting of motor overload (i·xt) – Lenze 8400 TopLine User Manual
Page 912: C00120, R load setting, C00118, C00117, 17 parameter reference
![background image](/manuals/566308/912/background.png)
17
Parameter reference
17.2
Parameter list | C00117
912
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00117
C00118
C00120
Parameter | Name:
C00117 | Status of brake output BD
Data type: UNSIGNED_8
Index: 24458
d
= 5F8A
h
Status message of brake output
Selection list
(read only)
Info
0 Inactive
Brake output is inactive
1 Active
Brake output is active
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00118 | DigOutX: Inversion
Data type: UNSIGNED_8
Index: 24457
d
= 5F89
h
The polarity of each digital output of the device can be inverted via this bit field.
Setting range
(min. hex value | max. hex value)
Lenze setting
0x00
0xFF 0x00 (decimal: 0)
Value is bit-coded: ( = bit set)
Info
Bit 0 Relay inverted
Relay inversion
Bit 1 DO1 inverted
Inversion of digital output 1
Bit 2 DO2 inverted
Inversion of digital output 2
Bit 3 DO3 inverted
Inversion of digital output 3
Bit 4 High current inverted
Inversion of high-current output
Bit 5
Reserved
Bit 6
Reserved
Bit 7
Reserved
Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00120 | Setting of motor overload (I²xt)
Data type: INTEGER_16
Index: 24455
d
= 5F87
h
Operating threshold for the "OC6: Motor overload (I²xt)" error message
• The response for reaching the threshold can be selected in
.
• The current thermal motor load is displayed in
Motor overload monitoring (I2xt)
Setting range
(min. value | unit | max. value)
Lenze setting
0.00
%
250.00 100.00 %
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100