4 frequency htl encoder (di1/di2, di6/di7), Frequency htl encoder (di1/di2, di6/di7), 6encoder/feedback system – Lenze 8400 TopLine User Manual
Page 352
6
Encoder/feedback system
6.4
Frequency HTL encoder (DI1/DI2, DI6/DI7)
352
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
6.4
Frequency HTL encoder (DI1/DI2, DI6/DI7)
Parameterisation dialog (cutout)
Parameter
Info
Lenze setting
Value Unit
Settings for HTL encoder at DI1/DI2
Fct. DI 1/2 200kHz
• Function of the digital inputs DI1 and DI2
0: DI1(6)=In / DI2(7)=In
FreqIn12: Encoder increment
• If the digital inputs DI1 and DI2 are used as
encoder inputs.
128 Incr./rev.
FreqIn12: Encoder filter time
• If the digital inputs DI1 and DI2 are used as
encoder inputs.
1.0 ms
FreqIn12: Encoder scanning time
• If the digital inputs DI1 and DI2 are used as
encoder inputs.
10 ms
Encoder evaluation method DigIn12 ( 355)
2: Comb. encoder method
Settings for HTL encoder at DI6/DI7
Fct. DI 6/7 10kHz
• Function of the digital inputs DI6 and DI7
0: DI1(6)=In / DI2(7)=In
FreqIn67: Encoder increment
• If the digital inputs DI6 and DI7 are used as
encoder inputs.
128 Incr./rev.
FreqIn67: Encoder filter time
• If the digital inputs DI6 and DI7 are used as
encoder inputs.
1.0 ms
FreqIn67: Encoder scanning time
• If the digital inputs DI6 and DI7 are used as
encoder inputs.
10 ms