C02238 | ls_writeparamlist: rated motor frequency, C02239 | ls_writeparamlist: rated motor voltage, C02240 | ls_writeparamlist: motor cosine phi – Lenze 8400 TopLine User Manual
Page 1243: C02238/1, C02238/2, C02238/3, C02238/4, C02239/1, C02239/2, C02239/3
![background image](/manuals/566308/1243/background.png)
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
1243
17
Parameter reference
17.2
Parameter list | C02238
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02238
C02239
C02240
Parameter | Name:
C02238 | LS_WriteParamList: Rated motor frequency
Data type: UNSIGNED_16
Index: 22337
d
= 5741
h
From version 12.00.00 onwards
: Parameter values (1st value ... 4th value) for optional
Setting range
(min. value | unit | max. value)
1
Hz
1000
Subcodes
Lenze setting
Info
C02238/1
50 Hz
: c89_val1
C02238/2
50 Hz
: c89_val2
C02238/3
50 Hz
: c89_val3
C02238/4
50 Hz
: c89_val4
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C02239 | LS_WriteParamList: Rated motor voltage
Data type: UNSIGNED_16
Index: 22336
d
= 5740
h
From version 12.00.00 onwards
: Parameter values (1st value ... 4th value) for optional
Setting range
(min. value | unit | max. value)
0
V
5000
Subcodes
Lenze setting
Info
C02239/1
400 V
: c90_val1
C02239/2
400 V
: c90_val2
C02239/3
400 V
: c90_val3
C02239/4
400 V
: c90_val4
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C02240 | LS_WriteParamList: Motor cosine phi
Data type: UNSIGNED_8
Index: 22335
d
= 573F
h
From version 12.00.00 onwards
: Parameter values (1st value ... 4th value) for optional
Setting range
(min. value | unit | max. value)
0.40
1.00
Subcodes
Lenze setting
Info
C02240/1
0.85
: c91_val1
C02240/2
0.85
: c91_val2
C02240/3
0.85
: c91_val3
C02240/4
0.85
: c91_val4
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100