C00941 | l_convw denominator, C00942 | l_convw conversion method, C00950 | l_interpolator_1: activation fb functions – Lenze 8400 TopLine User Manual
Page 1126: 17 parameter reference
17
Parameter reference
17.2
Parameter list | C00941
1126
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00941
C00942
C00950
Parameter | Name:
C00941 | L_ConvW denominator
Data type: INTEGER_16
Index: 23634
d
= 5C52
h
Setting range
(min. value | unit | max. value)
1
32767
Subcodes
Lenze setting
Info
C00941/1
1
: Denominator
C00941/2
1
: Denominator
C00941/3
1
: Denominator
C00941/4
1
: Denominator
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00942 | L_ConvW conversion method
Data type: UNSIGNED_8
Index: 23633
d
= 5C51
h
Selection list
0 no conversion
1 from [%] into [incr./ms]
2 from [incr./ms] into [%]
3 Factors signed
4 Factors unsigned
Subcodes
Lenze setting
Info
C00942/1
0: No conversion
: Conversion method
C00942/2
0: No conversion
: Conversion method
C00942/3
0: No conversion
: Conversion method
C00942/4
0: No conversion
: Conversion method
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00950 | L_Interpolator_1: Activation FB functions
Data type: UNSIGNED_8
Index: 23625
d
= 5C49
h
FB: Activation of signal interpolation and signal monitoring
Selection list
0 Off
1 On
Subcodes
Lenze setting
Info
C00950/1
0: Off
: Signal interpolation
C00950/2
0: Off
: Signal monitoring
C00950/3
0: Off
: Master value monitoring
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1