Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
865
16
Parameter change-over
16.1
Configuring parameter change-over via the »Engineer« parameterisation dialog
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
16.1.3
Functional settings
16.1.4
Error indication
With every run through the main program, one parameter of the definable parameter list is written
until the parameter list has been executed completely. If an error occurs,
displays an error
status and
displays the number of the list entry causing the error (in connection with the
selected value set).
• If several errors occur at the same time, only the first incorrect list entry will be displayed. Hence,
after elimination of the displayed error and another activation, more errors may be displayed.
• The parameter list will always be processed from beginning to end, even if errors occur in the
meantime.
Parameter
Lenze setting
Info
Execute Mode
(
)
0: by Execute
For writing the parameter list, two modes are
available:
• 0: by Execute (Lenze setting)
The writing of the parameter list is activated by a
FALSE/TRUE edge at the bExecute control input.
• 1: by Input Select
The parameter list is written when the selection
inputs bSelectWriteValue_1 and
bSelectWriteValue_2 are changed and once
during the initialisation of the controller.
Note: If the execute mode changes from "0: by
Execute" to "1: by Input Select", the parameter list
selected by the selection inputs is written once. In
the execute mode "1: by Input Select", the parameter
list then is only written again when a change occurs
on the selection inputs .
Definable parameter list
(
1: On
Switch on/off parameter changeover for the
definable parameter list.
Motor data parameter list
(
0: Off
Switch on/off parameter changeover for the motor
data parameter list.