C00432 | ls_resolver: bfail selection, C00434 | oxu/i: gain, N in – Lenze 8400 TopLine User Manual
Page 976: C00432/1, C00434/1, C00434/2, 17 parameter reference
17
Parameter reference
17.2
Parameter list | C00432
976
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00432
C00434
Parameter | Name:
C00432 | LS_Resolver: bFail selection
Data type: UNSIGNED_16
Index: 24143
d
= 5E4F
h
From version 13.00.00
Bit coded setting which events cause the bFail output to be set.
Setting range
(min. hex value | max. hex value)
0x0000
0xFFFF
Value is bit-coded:
Bit 0 Resolver wire breakage
Bit 1 KTY open circuit
Bit 2
Reserved
Bit 3
Reserved
Bit 4
Reserved
Bit 5
Reserved
Bit 6
Reserved
Bit 7
Reserved
Bit 8
Reserved
Bit 9
Reserved
Bit 10
Reserved
Bit 11
Reserved
Bit 12
Reserved
Bit 13
Reserved
Bit 14
Reserved
Bit 15
Reserved
Subcodes
Lenze setting
Info
C00432/1
0x0001
: bFail selection
Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00434 | OxU/I: Gain
Data type: INTEGER_16
Index: 24141
d
= 5E4D
h
Gain of the analog outputs
Setting range
(min. value | unit | max. value)
-199.99
%
199.99
Subcodes
Lenze setting
Info
C00434/1
100.00 %
O1U: Gain
C00434/2
100.00 %
O2U: Gain
C00434/3
100.00 %
O1I: Gain
C00434/4
100.00 %
O2I: Gain
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100