Function library
19.1
Function blocks
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
wState
WORD
Status (bit-coded)
Bit 1 Positioning program ready to start/program end reached.
Bit 2 Positioning program is running.
Bit 3 Positioning program started, break active.
Bit 4 Positioning program stopped.
Bit 5 Positioning program reset.
Bit 6 Positioning program completed.
Bit 7 Time monitoring for "
" action has been triggered.
Bit 8 Wrong value at branch input.
Bit 15 Fault is active.
wActStep
WORD
Current step being processed by the positioning program.
0 Positioning program not started.
1 ... 100 Current step
wDigitalOutputs
WORD
Sequencer outputs 1 ... 16 (bit coded)
• The sequencer outputs can be set to "0" or "1" by the "switching" action type
during the runtime of the positioning program.
• For providing individual control signals, e.g. the converter
FB
can be connected to this output.
Bit 0 Sequencer output 1
Bit 1 Sequencer output 2
... ...
Bit 15 Sequencer output 16
nSet_a
INT
Speed setpoint which is output in the "
• If no "Stand-by" action is active, the value "0" is output.
wProfileNumber
WORD
Display of the profile data set active in the current step
bProgramBusy
BOOL
Status signal "Positioning program is running"
FALSE Positioning program not started or stopped.
TRUE Positioning program is running.
bStateReady
BOOL
TRUE Positioning program ready to start/program end reached.
bStateRun
BOOL
TRUE Positioning program is running.
bStatePause
BOOL
TRUE Positioning program started, break active.
bStateBreak
BOOL
TRUE Positioning program stopped.
bStateReset
BOOL
TRUE Positioning program reset.
bStateDone
BOOL
TRUE Positioning program completed.
bWatchdogActive
BOOL
TRUE Time monitoring for "
" action has been triggered.
bErrBranch
BOOL
TRUE Wrong value at branch input.
bErrActive
BOOL
TRUE Fault is active.
Identifier
Data type
Value/meaning