C00061 | heatsink temperature, C00062 | temperature inside the controller, C00063 | motor temperature – Lenze 8400 TopLine User Manual
Page 899: C00061, C00063/1, Has reac, C00063/2, 17 parameter reference

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
899
17
Parameter reference
17.2
Parameter list | C00061
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00061
C00062
C00063
Parameter | Name:
C00061 | Heatsink temperature
Data type: INTEGER_16
Index: 24514
d
= 5FC2
h
Display of the current heatsink temperature
Display range
(min. value | unit | max. value)
-50
°C
150
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00062 | Temperature inside the controller
Data type: INTEGER_16
Index: 24513
d
= 5FC1
h
From version 02.00.00
Display of the current temperature inside the controller
Display range
(min. value | unit | max. value)
-200
°C
200
Subcodes
Info
C00062/1
Interior temperature of CU
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00063 | Motor temperature
Data type: INTEGER_16
Index: 24512
d
= 5FC0
h
Display of the current motor temperature
Display range
(min. value | unit | max. value)
-200
°C
250
Subcodes
Info
C00063/1
Motor temperature
C00063/2
Motor temperature via resolver
C00063/3
Motor temperature via MultiEncoder
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1