Ck05: following error 1 [xx.0184.00153, Ck06: following error 2 [xx.0184.00154, Ck07: travel range limit exceeded [xx.0184.00155 – Lenze 8400 TopLine User Manual
Page 726: Ck08: home position unknown [xx.0184.00156, Ck09: positioning mode invalid [xx.0184.08005, Ck16: time overflow manual control, Error m, Ck07: travel range limit exceeded, Ck05: error, following error 1, Ck06: error, following error 2
10
Diagnostics & error management
10.9
Error messages of the operating system
726
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Ck16: Time overflow manual operation [xx.0184.00064]
Ck05: Following error 1 [xx.0184.00153]
Ck06: Following error 2 [xx.0184.00154]
Ck07: Travel range limit exceeded [xx.0184.00155]
Ck08: Home position unknown [xx.0184.00156]
Ck09: Positioning mode invalid [xx.0184.08005]
Response (Lenze setting printed in bold)
0: No Reaction 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked 5: Warning 6: Information
Cause
Remedy
PC manual control: The connection monitoring has
tripped.
• The online connection between the PC and the
controller has been interrupted for a longer period of
time than the timeout set in
• Check communication link between PC and
controller.
• Check voltage supply/function of the controller.
• Adjust the timeout (
).
Response (Lenze setting printed in bold)
Setting:
( Adjustable response)
0: No Reaction 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked 5: Warning 6: Information
Cause
Remedy
MCK: Following error limit 1 (
) has been
exceeded.
• Optimise control mode.
• Increase following error limit.
• Deactivate following error monitoring.
Response (Lenze setting printed in bold)
Setting:
( Adjustable response)
0: No Reaction 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked 5: Warning 6: Information
Cause
Remedy
MCK: Following error limit 2 (
) has been
exceeded.
• Optimise control mode.
• Increase following error limit.
• Deactivate following error monitoring.
Response (Lenze setting printed in bold)
Setting:
( Adjustable response)
0: No Reaction 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked 5: Warning 6: Information
Cause
Remedy
MCK: The maximum travel distance has been exceeded.
• The maximum travel distance is displayed in
• Check profile parameters.
• Deactivate travel range limit monitoring.
Response (Lenze setting printed in bold)
Setting:
( Adjustable response)
0: No Reaction 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked 5: Warning 6: Information
Cause
Remedy
MCK: Home position is unknown.
Perform homing.
Response (Lenze setting printed in bold)
Setting:
( Adjustable response)
0: No Reaction 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked 5: Warning 6: Information
Cause
Remedy
MCK: The positioning mode defined via the
wPosProfileMode input is not supported.
Define a valid positioning mode.