C02252 | ls_writeparamlist: kp position controller, C02250/1, C02250/2 – Lenze 8400 TopLine User Manual
Page 1246: C02250/3, C02250/4, C02251/1, C02251/2, C02251/3, C02251/4, C02252/1
![background image](/manuals/566308/1246/background.png)
17
Parameter reference
17.2
Parameter list | C02250
1246
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02250
C02251
C02252
Parameter | Name:
C02250 | LS_WriteParamList: Filter time - oscill. damping
Data type: UNSIGNED_8
Index: 22325
d
= 5735
h
From version 12.00.00 onwards
: Parameter values (1st value ... 4th value) for optional
Setting range
(min. value | unit | max. value)
2
ms
250
Subcodes
Lenze setting
Info
C02250/1
32 ms
: c235_val1
C02250/2
32 ms
: c235_val2
C02250/3
32 ms
: c235_val3
C02250/4
32 ms
: c235_val4
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C02251 | LS_WriteParamList: Oscillation damping field weakening
Data type: UNSIGNED_8
Index: 22324
d
= 5734
h
From version 12.00.00 onwards
: Parameter values (1st value ... 4th value) for optional
Setting range
(min. value | unit | max. value)
0
40
Subcodes
Lenze setting
Info
C02251/1
14
: c236_val1
C02251/2
14
: c236_val2
C02251/3
14
: c236_val3
C02251/4
14
: c236_val4
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C02252 | LS_WriteParamList: Kp position controller
Data type: UNSIGNED_16
Index: 22323
d
= 5733
h
From version 12.00.00 onwards
: Parameter values (1st value ... 4th value) for optional
Setting range
(min. value | unit | max. value)
0.00
1/s
500.00
Subcodes
Lenze setting
Info
C02252/1
5.00 1/s
: c254_val1
C02252/2
5.00 1/s
: c254_val2
C02252/3
5.00 1/s
: c254_val3
C02252/4
5.00 1/s
: c254_val4
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100