9 stop, 1 parameter setting, 2 requesting the operating mode – Lenze 8400 TopLine User Manual
Page 648: Stop, Parameter setting, Requesting the operating mode, 9basic drive functions (mck)
9
Basic drive functions (MCK)
9.9
Stop
648
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
9.9
Stop
If the "normal stop" operating mode is active, the drive is brought to a standstill with a
parameterisable deceleration ramp.
9.9.1
Parameter setting
Short overview of parameters for "Normal stop" operating mode:
9.9.2
Requesting the operating mode
Request for "Normal stop" operating mode by means of the
:
If the MCKInterface is connected upstream to the Motion Control Kernel and if the operating mode
FB, the wOperationMode and bOperationMode_1...8 process
inputs are available.
Parameter
Info
Lenze setting
Value Unit
Normal stop: Deceleration
720.0000 units/s2
Stop: S-ramp time
0.000 s
MCK control word
Bit 31
...
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
OpMode_Bit3
OpMode_Bit2
OpMode_Bit1
OpMode_Bit0
X
...
X
0
1
0
0
X = Status not significant